5 V relay, bare part

Motors & Actuators

5 V relay, bare part

A bare 5 V relay uses a coil and mechanical contacts to switch a separate low-voltage load from a control signal.

Owned by clubQuantity: 3

Coil/logic control; isolated mechanical contacts

What it does

Separates coil/control current from switched contact current. Common, normally-open and normally-closed terminals choose whether a load is connected when the coil is off. The contact rating and the coil voltage describe different circuits; a printed AC rating does not automatically apply to a DC inductive load.

Useful specifications

Coil
5 V established
Contact/current/inrush limits
Exact marking/datasheet required
How it works

Current through the coil creates a magnetic field that pulls an armature, moving contacts against a spring. When drive stops the spring restores the contact state. The coil is inductive and produces a voltage transient on turn-off; contacts can arc and wear while switching loads.

Wound electromagnetic coil, magnetic core/armature, return spring and movable metal contacts; carriers add a control transistor and possibly an optocoupler.

Recognize the part

Box-shaped relay with pins underneath, no carrier PCB. Read the coil/contact markings and locate the contact diagram; do not infer every pin from cube shape.

Also called: relay, 5v relay, 5V relay

How to use it

Use a transistor/driver with adequate coil current and a suppression diode across the DC coil, cathode to positive. Identify coil/contact pins from the exact diagram. Begin with an isolated low-voltage load and verify COM/NO/NC by continuity. Keep load wiring separate from logic and match contact ratings to voltage, current, load type and inrush.

Know before using

Limits

  • Slow switching, clicking and contact wear.
  • Mechanical relays are unsuitable for fast PWM.
  • Some low-cost carriers lack clearance for hazardous voltages.

Common mistakes

  • Confusing coil voltage with contact voltage.
  • Powering a bare coil from GPIO.
  • Assuming every module is active-high or truly isolated.

Care and safety

  • Use low-voltage club experiments; exposed hobby carriers are not an authorization to switch mains.
  • Suppress coil kickback and verify contact/inrush ratings.

What you need with it

required

Isolated low-voltage test load and supply within the exact contact rating

required for contact demonstration

A separate isolated load source and test load make COM/NO/NC behavior observable.

PN2222 NPN transistor

A verified NPN switch can sink coil current while GPIO supplies only base drive.

  • Check PN2222 pinout, coil current, saturation drive and dissipation; choose another driver if insufficient.
Owned type; verify quantity, rating and fit for this use.

1 kΩ resistor

required with bjt driver

A calculated base resistor limits/control base current.

  • 1 kΩ is an owned candidate, not a guaranteed saturation value for every relay coil.
Owned type; verify quantity, rating and fit for this use.

1N4007 rectifier diode

required with unclamped coil

A reverse-biased diode across the coil catches the turn-off transient.

  • Cathode goes to coil positive; reversal shorts the energized supply. Verify current/response requirements.
Owned type; verify quantity, rating and fit for this use.

What can I build?

Related owned hardware

Read the conditions before connecting parts. A relationship can involve a driver, controller or a redesigned circuit.

switched load control

Arduino Uno R3

  • An Uno state machine can command a low-voltage load switch through a suitable coil/input driver.

Connection conditions

  • Use only identified coil/carrier supply and logic levels; contact ratings depend on load/inrush.
  • Project guidance is for isolated low-voltage loads; the catalog does not certify mains clearances.

manual interlock

Slide switch

  • A low-current slide-switch input can request or inhibit relay activation in firmware.

Connection conditions

  • Software inhibition is not a safety-rated emergency stop.

support hardware

PN2222 NPN transistor

  • A verified NPN switch can sink coil current while GPIO supplies only base drive.

Connection conditions

  • Check PN2222 pinout, coil current, saturation drive and dissipation; choose another driver if insufficient.

support hardware

1 kΩ resistor

  • A calculated base resistor limits/control base current.

Connection conditions

  • 1 kΩ is an owned candidate, not a guaranteed saturation value for every relay coil.

support hardware · flyback protection

1N4007 rectifier diode

  • A reverse-biased diode across the coil catches the turn-off transient.
  • A correctly polarized coil-parallel diode gives relay current a decay path at turn-off.

Connection conditions

  • Cathode goes to coil positive; reversal shorts the energized supply. Verify current/response requirements.
  • Cathode to coil positive; the diode affects relay release time and must fit coil current.

When would I use each?

Relays

Same low-voltage switching class after accounting for bare-versus-carrier circuitry.

Use a verified carrier to simplify low-voltage demonstrations. A bare relay teaches coil-drive design. Neither has a catalog-certified mains wiring arrangement, and an optocoupler symbol alone does not prove an isolated assembled system.

Owned substitutions

Single-channel relay module

partial redesign

The bare/carrier pair provides the same underlying component class when the fitted circuitry is identified.

Required changes

  • Rewire package/header pins and add or account for carrier bias/driver/suppression components.
  • Check supply, output polarity and signal voltage.
  • Carrier circuitry is not assumed from board shape.
  • The carrier does not inherently improve the sensing die or contact rating.

Documentation

Inventory record and image evidence

Quantity: 3 · quantity confidence: high

Known countable purchase/BOM contributions. Each source line is a total; do not multiply by container count or add photo observations.

Ownership: source-backed club holding. Identity confidence: high.

Identity follows exact kit sheet/BOM; expected quantity is not a physical stocktake.

V1 establishes the catalog identity. Technical references explain the named device or component class; unverified carrier-specific ratings and pinouts are not asserted.

Source holdings

Parent kits

Original V3 image confidence: 90% · high. Component crop tied to an owned kit and its source mapping; selected by form rather than filename alone.

Original V3 image source: Freenove FNK0020 older sheet (owned kit reference). Images describe identity and form; they do not establish quantity.

Displayed image source: ELEGOO — The Most Complete Starter Kit for MEGA 2560 tutorial — The Most Complete Starter Kit for MEGA V1.0.2021.05.13.pdf, page 203, image xref 737 (supplied selection metadata).

Bare relay has no carrier and a visible SRD-05VDC-SL-C marking supporting the canonical 5 V coil class. It is a representative package, not proof of club manufacturer/contact ratings; retain the actual-marking safety requirement.

Illustration © ELEGOO. All rights reserved. Used for the Engineering Club educational website under club-reported permission; no broader license is granted.