Inventory project / intermediate

Sample an RC charge and decay curve

Observe a nominal one-second RC transient using an ADC input with explicit loading and timing limits.

Core electronics available

The idea

Several signals/components, buses, calibration, state or timing; requires explicit integration checks.

RC time constantcapacitor polarityADC source impedance

Expected source-backed quantity supports one build in isolation; physical availability, allocation, condition and simultaneous builds are not guaranteed. Ordinary host USB power, software and a programming computer are prerequisites, not inferred inventory types.

Hardware and roles

1 kΩ resistor

Current-limited switch discharge path

For one demonstrator: 1

Quantity: 30

External requirements

  • workflow · Required Programming computer, appropriate software and a verified ordinary host USB power/data connection where used

Why these parts fit together

  1. Wire a rated polarized capacitor safely and compute the nominal RC constant. Put the discharge button through a 1 kΩ resistor, not directly across the capacitor.
  2. Use sufficiently slow acquisition/settling and compare the analog meter/readout.
  3. Fit a charge/decay curve and explain tolerance, leakage and ADC loading rather than expecting exact one-second timing.

Check before building

  • Do not use GPIO to short a charged capacitor; use a suitable discharge path.

What success looks like

Fit a charge/decay curve and explain tolerance, leakage and ADC loading rather than expecting exact one-second timing.