PiCrawler / Hardware Expansion / Telemetry & Data / Control Systems
IMU Gait Motion Recorder and Analyzer
Add orientation observations before attempting feedback stabilization.
Desired physical result & engineering purpose
A live roll/pitch/rate trace accompanies repeat gait trials and fall/tilt annotations.
Engineering goal
Qualify mounting, bias, sample timing and analysis of body motion.
Why investigate it?
Highest-value first instrumentation addition, with an existing club candidate.
Additional hardware required. Qualify mounting, bias, sample timing and analysis of body motion.
Preconditions & requirements
Complete recovery, preservation and controlled motion qualification first.
- Recovered, calibrated robot and controlled motion baseline
- Robot Telemetry and Observability Station
- Custom Gait Laboratory
Stock baseline
- Raspberry Pi 5 / 4 GB
- assembled PiCrawler with 12 servos
Additional requirements
- Reviewed GY-521 MPU-6050 carrier
- Rigid lightweight mount
Ownership and condition must be checked in Inventory and at the machine; no proposed addition is automatically installed.
Relevant APIs & editing locations
future reviewed MPU-6050 driver over I2C· see source modules / proposed interfacePicrawler.do_action· Public user API
Modules to read / proposed files to author
club IMU acquisition/filter/logger (proposed)
Club modules named here are proposed design locations. Preserve the recovered vendor code; prefer owned behaviors and validated data before a pinned vendor fork.
Modification layers
- 2 · User Python — New behavior and experiments consuming existing APIs
- 4 · Application architecture — State machine, queue, watchdog, camera owner and telemetry
- 8 · Sensor and electronics expansion — Orientation, range coverage, contact/environment sensors and status displays
- 9 · Mechanical modification — Feet, lightweight mounts/trays/guards, cable routes and measured geometry
Related changes
- Read a new I2C sensor · back up Connector/pin map, baseline bus list and electrical review
Proposed implementation sequence
- Review carrier voltage/pull-ups/address
- Mount rigidly and measure axis transform
- Log raw accel/gyro and stationary bias
- Compare gaits with synchronized video before control
Begin with inert/offline validation. Hardware initialization and motion need the explicit physical gates; this plan is not an executable script.
Acceptance evidence & failure modes
Evidence to collect
- Sensor/body frame and bias record
- Raw versus estimated orientation labeled
- Repeatable vibration/tilt metrics with sample age
Failure cases to investigate
- Dynamic acceleration corrupts tilt estimate
- Yaw drifts without reference
- Vibration/loose mount
- I2C fault disrupts HAT
Diagnostic specifications and stop limitations · Measurement protocols
Related Learn content & system crossovers
Project concepts: sensor frame; gyro bias; gravity estimate; aliasing; drift. The links below resolve to existing Learn concepts; domain-specific Python/robotics topics are not invented Learn routes.
Technical reading
Dependencies & related proposals
Required first
- Recovered, calibrated robot and controlled motion baseline
- Robot Telemetry and Observability Station
- Custom Gait Laboratory
Related ideas
- Measured Joint and Contact Architecture Study
- Custom Gait Laboratory
- Known-course Localization and Navigation Research
- Bounded Body Orientation Feedback Experiment
- Robot Telemetry and Observability Station
Later consumers
Remaining gates & source evidence
- Measure behavior on recovered hardware; source feasibility is not a bench result.
Implementation: source-grounded design proposal, not implemented. Physical verification: not tested. Installed environment, calibration, sensors and actuator condition require actual recovery evidence.