When would I use each?
Use DHT11 only when humidity matters and modest accuracy is sufficient. DS18B20 provides addressed digital temperature. LM35 produces a temperature-proportional voltage with supply constraints. Thermistors are useful for resistance/calibration lessons; nominal resistance alone does not justify Celsius values.
Use dimensions and selectionGuidance to choose; group membership alone does not establish equivalent measurements or physical/electrical interchangeability.
| Feature | DHT11 temperature and humidity sensor, bare part | DHT11 humidity-temperature module | DS18B20 temperature sensor module |
|---|---|---|---|
| Quantity | Temperature and relative humidity | Temperature and relative humidity | Temperature only |
| Selection limit | Slow/coarse legacy ranges; package wiring | Carrier is easier to wire but does not improve DHT11 die accuracy | Conversion delay and bus pull-up constraints |
| Host conversion | Pulse-timed DHT11 message/checksum; pull-up | Same protocol; inspect carrier bias | Dallas 1-Wire conversion/address |
| Feature | LM35 analog temperature sensor module | 10 kΩ thermistor | Analog thermistor temperature module |
|---|---|---|---|
| Quantity | Temperature only | Temperature-dependent resistance | Temperature-dependent carrier voltage |
| Selection limit | Supply/analog-reference error | Beta/tolerance/reference-temperature unknown | Carrier curve and pull-up rail unknown |
| Host conversion | ADC plus nominal 10 mV/°C transfer | Divider/ADC plus actual curve/calibration | ADC plus actual curve/calibration |